clamp on ultrasonic flow meter installation guidelines

Atrato Ultrasonic Flow Meter Installation Page 2 For successful ultrasonic flow meter installation locate the flow meter in a sheltered position away from falling water. The meter is housed in an.


6000 Series Portable Ultrasonic Flow Meter

They are among the most cost-effective flow measurement technologies for measuring volumetric flow rates of liquids.

. At the time of preparation of this fact sheet the price for a single unit ranged between 2000 and 13000. The sensors measure flow by transmitting and receiving ultrasonic signals directly through the pipe wall and the medium. Besides the transducer installation site should be at least 30D away from the pump.

The Sitrans FS230 meter has been designed to make installation and configuration easier and more efficient even for those previously unfamiliar with clamp-on technology. It is suitable for measuring the volumetric flow of liquids in a wide variety of applications including bi-directional flow applications. Transit-time is the preferred mode.

This means low install costs. To optimize every operation Siemens offers a comprehensive selection of clamp-on flow sensors transmitters and complete flow systems. Understanding Installation Problems with Ultrasonic Clamp On Flowmeters.

Refer to the following table for more details. Please contact the factory for more information. This benefit becomes greater and greater as the pipe size is increased.

Up to 15 cash back Flow Measurement of Drinking Water Clamp-on Ultrasonic Flow is a non-intrusive technology that is applied to the outside of process piping. Flexim manufactures a full range of ultrasonic flow measurement equipment and instruments for industrial and commercial applications. Ultrasonic flowmeters consist of clamp-on transducers that are attached on the outside wall of the pipe with flowing water Figure 1.

Ideal for clean liquid applications this transit-time measurement technology reduces installation downtime and provides significant cost effectiveness when compared to inline flow measurement equipment. A Clamp-On Ultrasonic Flowmeter for Gases A Clamp-On Ultrasonic Flowmeter for Gases D. The transducers should be installed at a pipe section where the length of the straight pipe on the upstream side is at least 10D and on the downstream side is at least 5D.

In the first of our application notes for ultrasonic clamp on meters it is astoundingly clear that meter quality is a significant contributor to attaining accurate flow measurement results. Monitoring your processes with accurate clamp-on ultrasonic flow measurement leads to higher transparency improved productivity and a better bottom line. January 29 2020.

If the flow meter screen still fails to illuminate the batteries may require replacement. Flexim a globally recognized leader in the manufacture of ultrasonic flow meters provides us with a video that steps through the installation process with recommendations and guidance along the way. 12 TYPICAL FP-4400 FLOW METER INSTALLATION The FP-4400 Portable Clamp-on Ultrasonic Flow Meter utilizes clamp-on signal transducers that mount on the outside wall of the pipe.

VersaFlow Clamp-On Ultrasonic flow meters are designed for applications where a customer is unwilling or unable to cut into the process measurement line to install an in-line meter. Non-Contacting Flow Measurement Ultrasonic transducers clamp on the outside of pipes allowing for installation without system shutdown and produces no pressure drop. The VorTek U42 Commercial Series and U43 Water Series of Ultrasonic Flow Meters.

Ideally flexible tubes should be used. The basis for this level of usability is the transmitters advanced human machine interface HMI which features a customizable 240 x 160 graphic display and four capacitive navigation keys. Tek-Clamp 1200A Ultrasonic Clamp On Flow Meter is designed to measure the fluid velocity of liquid in a full or closed pipe.

12 TYPICAL F-4300 FLOW METER INSTALLATION The F-4300 Ultrasonic Flow Meter utilizes clamp-on signal transducers that mount on the outside wall of the pipe. During ultrasonic flow meter installation care must be taken to ensure that the end fittings on the meter are not stressed during use. The price depends on the type and range of flows that can be measured.

This is the first in a look behind the technology of the winning products. How the flow rate is determined varies depending on the nature of the application. Here D stands for pipe outer diameter.

The ultrasonic flowmeter has a wide range and the flow rate can usually be from 1 ms to 30 ms or a larger flow rate under the condition of ensuring high measurement accuracy. Benefits of Clampon Meters The main benefit of a clampon meters is that the pipe does not need to be cut as seen with typical flow meter installations ie. It is a measurement system which is both easy to install and use.

Installation Guidelines for Inline Ultrasonic Flow Meters. If the flow meter fails to turn on open the battery compartment remove the batteries check their integrity and replace in the flow meter. Browse our Equipment Guide categories to find and contact your manufacturer.

VorTek clamp-on ultrasonic flow meters are clamped on to the outside of the pipe and never directly contact the media inside the pipe. It is suitable for measuring the volumetric flow of liquids in a wide variety of applications including bi-directional flow applications. With clamp-on ultrasonic flow meters the key to a good installation is making sure that the pipe it is affixed to has acoustical properties that will allow the ultrasonic principle of measurement to function properly.

Available in configurations for pipe line sizes from DN15 to DN4000 12 to 160 the clamp-on design offers a cost-effective means of measuring. Repeat the start sequence. It is suitable for measuring the volumetric flow of liquids in a wide variety of applications including bi-directional flow applications.

As a leader in the field of clamp-on ultrasonic flow measurement FLEXIM offers the ideal flow meter solutions - even for the most demanding challenges. In future parts we will be discussing installation effects in more detail. Always refer to your product manual for your exact flow meter.

Up to 15 cash back Overview. The DigitalFlow GC868 Clamp-On Ultra-sonic Flowmeter for Gas discussed in this ar-ticle is a winner in this years Flow Control magazines Innovation Awards. A clamp-on ultrasonic flow meter consists of at least two ultrasonic sensors mounted externally to a pipe.

Therefore the selection of its diameter can generally be smaller than the size of the main pipeline which can reduce the overall investment in the straight pipe. User-Friendly Operating System Built-in keypad and simple menu system for fast and easy programming of pipe diameter pipe material liquid type and measurement units. 13 TYPICAL F-4300 FLOW METER The F-4300 Ultrasonic Flow Meter utilizes clamp-on signal transducers that mount on the outside wall of the pipe.

The flow velocity and direction are accurately determined. The Tek-Clamp 1200A operates according to the difference in the Transit Time of Flight measured and determines the flow velocity by measuring the travel time of a pulse from one transducer. With traverse type set-up coupling pastes pipe sizes particulatebubbles pipe.


Ultrasonic Flow Meter The Engineering Knowledge


How Ultrasonic Flow Meter Works Gaimc Group


Common Mounting Configurations Z Method Top V Method Middle And W Download Scientific Diagram


Ultrasonic Flow Meter Guide


Portable Clamp On Ultrasonic Flow Meter For Water Ato Com


U1000mkii Fm Fixed Clamp On Ultrasonic Flow Meter Micronics


F 4300 Clamp On Ultrasonic Flow Meter Thermal Energy Measurement System Onicon Flow And Energy Measurement


Ultrasonic Flow Meter Guide


Clamp On Ultrasonic Flow Meters Installation Guidelines Rms Engineering


Ultrasonic Flow Meter The Engineering Knowledge


Ultrasonic Flow Meter Installation Process Ultrasonic Flow Meters Small Bore Low Flow Non Invasive


Clamp On Ultrasonic Gas Flow Meters


Si 3403 Clamp On Ultrasonic Flow Meter Sino Inst


How To Install Clamp On Ultrasonic Flowmeters I Mega Instrument


How To Install Clamp On Ultrasonic Flowmeters I Mega Instrument


How To Install Clamp On Ultrasonic Flowmeters I Mega Instrument


Clamp On Ultrasonic Flow Meters Installation Guidelines Rms Engineering


Portable Ultrasonic Flow Meter Installation Tutorial How To Solve No Signal Message Youtube


How To Install Clamp On Ultrasonic Flowmeters I Mega Instrument

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel